This and many other products are now available for order online and pickup at the Power Equipment Direct warehouse in Bolingbrook, Illinois or at a Ferguson location near you.
Answer:
Your nearest pickup location within a 50-mile radius is automatically selected when you enter the site. To change your pickup location and see availability for other nearby locations, click the "Change Pickup Location" link on the product page or in the cart.
Answer:
Eligible items will have the Local Pickup option available both on the product page and in the cart. Select this option for all items you wish to pick up. Please note that Local Pickup can only be scheduled online at this time.
Answer:
Items are usually ready for pickup the same day the online order is placed, but this will depend on order volume and time of day. When your order is ready, you will receive an email including specific pickup instructions. Make sure to check your junk/spam folder. Orders not picked up within two business days may be canceled. You should opt to have your items shipped if you cannot pick them up promptly.
Answer:
During checkout, you will be prompted to enter the name, mobile phone number, and email address of the person who will be picking up the order. For your protection, only you or your designated pickup party may pick up your order. You will need your order confirmation and a government-issued photo ID to pick up your order.
Answer:
Not all items are available at all locations, so pickup availability will vary based on the selected store. Additionally, some items ship directly from our manufacturer partners and are not available for pickup. You can use the "Change Pickup Location" link to check for availability at nearby Local Pickup locations.
Answer:
Due to packaging, shipping costs, and other factors, some items cannot be shipped and are offered exclusively through Local Pickup.
Answer:
Credit/debit cards, Apple Pay, Google Pay, PayPal, and financing are accepted for Local Pickup orders.
Answer:
Make sure to have your order confirmation and a government-issued photo ID available when picking up your order. Check the item dimensions and ensure the items will fit in your vehicle. Bring any straps and other materials that will be needed to secure the items for transport.
New NewThis product is new and has never been used. It's in its original packaging, which has not been opened.
Weight
145 Pounds 145 PoundsTotal weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
Product Category
Furnace
UPC
663051560932
View More
+Share This Product
Recommended Accessories
Required AccessoriesAdd All Required
Installation Accessories
Features
Features
Overview for Goodman GCVC961005CN
Goodman established itself as the largest HVAC manufacturer in the US by producing high-quality, efficient equipment and providing it to homeowners at a great value. The GCVC96 furnace uses a pair of steel heat exchangers to convert 96% of the energy used into comfort, Goodman's highest mark for a two-stage furnace. It is equipped with an advanced variable-speed blower motor, which scales circulation to the specific demands of your application in real-time. The GCVC961005CN was designed with multiple options for the unit's gas, electric, and venting connections and orientation, ensuring a painless and quick installation. It even features a self-diagnosing control board that makes maintenance a breeze. If you're looking for consistent comfort and incredible efficiency from a two-stage furnace, it's tough to beat Goodman's GCVC96.
Advanced Heat Exchanger Design
The GCVC96 furnace employs a reliable dual-diameter tubular heat exchanger design. Aluminized steel is used for incredibly efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance the heat exchanger's dependability and longevity.
Secondary Heat Exchanger
This furnace produces additional heat by directing combustion gases through a secondary heat exchanger before they are vented. The secondary heat exchanger is made of corrosion-resistant stainless steel and it is sloped to prevent condensate build-up.
Quiet Comfort
The blower and gas valve of the GCVC961005CN were selected for their incredibly low sound levels. Additionally, this unit offers an airflow system and fan speed options that allow it to operate quietly while providing consistent comfort.
Venting Options
The GCVC961005CN offers several venting options to streamline installation in a variety of applications. It can be used in either a two-pipe direct vent setup or a single-pipe configuration with combustion air.
Secure Cabinet
All GCVC96 furnaces are protected by a durable steel cabinet rated for less than 2% air leakage. The heat exchanger section is insulated to prevent heat loss and the return side of the cabinet is solid and airtight.
ComfortBridge Compatible
This furnace is compatible with Goodman's ComfortBridge communicating controls. ComfortBridge control streamlines the installation and maintenance processes further by automatically detecting your equipment and providing diagnostics and troubleshooting.
Auto-Comfort
Goodman's Auto-Comfort mode is available in applications where the GCVC961005CN is used to distribute cooled air. This mode scales output up to the cooling demand in stages for improved comfort, efficiency, and dehumidification.
Easy Integration
The GCVC961005CN makes it simple to enhance your system with a humidifier and an electronic air cleaner; just wire them directly to the low-voltage terminals on the control board.
Extended Warranty
Goodman offers a 10-year limited unit replacement and parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See the "Manuals" tab for more information.
Specifications
Specifications
Overview
Product Category
Furnace
UPC
663051560932
General Information
Type
Gas Furnace
Product Line
GCVC96
Product Category
Furnace
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Two Stage
Blower Motor Type
ECM Variable-Speed
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow/Horizontal
Gas Conversion Kit
Available
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
Nationwide (Except CA)
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
96 %
Heating BTU
100000
High Fire Input
100000 BTU
High Fire Output
96000 BTU
Low Fire Input
70000 BTU
Low Fire Output
67200 BTU
Maximum Air Flow
2000 CFM
Ultra Low NOx Emissions Ultra Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
No
Low NOx Emissions Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx.
Yes
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
14.4 Amps
Recommended Breaker Size
20 Amps
Dimensions
Flue Connection Size
2 or 3 Inches
Cabinet Width
21 Inches
Product Height
34 1/2 Inches
Product Width
21 Inches
Product Depth
28 3/4 Inches
Product Weight
145 Pounds
Shipping Weight
145 Pounds
Certifications
Energy Star Listed
Yes
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
7368844
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
+Thank You For Submitting Your QuestionYour submission has been sent successfully. Please give our product specialists up to two business days to respond.