This and many other products are now available for order online and pickup at the Power Equipment Direct warehouse in Bolingbrook, Illinois or at a Ferguson location near you.
Answer:
Your nearest pickup location within a 50-mile radius is automatically selected when you enter the site. To change your pickup location and see availability for other nearby locations, click the "Change Pickup Location" link on the product page or in the cart.
Answer:
Eligible items will have the Local Pickup option available both on the product page and in the cart. Select this option for all items you wish to pick up. Please note that Local Pickup can only be scheduled online at this time.
Answer:
Items are usually ready for pickup the same day the online order is placed, but this will depend on order volume and time of day. When your order is ready, you will receive an email including specific pickup instructions. Make sure to check your junk/spam folder. Orders not picked up within two business days may be canceled. You should opt to have your items shipped if you cannot pick them up promptly.
Answer:
During checkout, you will be prompted to enter the name, mobile phone number, and email address of the person who will be picking up the order. For your protection, only you or your designated pickup party may pick up your order. You will need your order confirmation and a government-issued photo ID to pick up your order.
Answer:
Not all items are available at all locations, so pickup availability will vary based on the selected store. Additionally, some items ship directly from our manufacturer partners and are not available for pickup. You can use the "Change Pickup Location" link to check for availability at nearby Local Pickup locations.
Answer:
Due to packaging, shipping costs, and other factors, some items cannot be shipped and are offered exclusively through Local Pickup.
Answer:
Credit/debit cards, Apple Pay, Google Pay, PayPal, and financing are accepted for Local Pickup orders.
Answer:
Make sure to have your order confirmation and a government-issued photo ID available when picking up your order. Check the item dimensions and ensure the items will fit in your vehicle. Bring any straps and other materials that will be needed to secure the items for transport.
Buderus G215/4 - 171K BTU - 86.2% AFUE - Hot Water Oil Boiler - Chimney Vent - Includes Beckett AFG Burner
The Buderus G215 oil boiler is a complete home oil heating solution that works equally well in both new construction and renovations of existing buildings. The three pass heat exchanger extracts every last possible BTU of heat energy out of the oil supply, resulting in higher efficiencies across the board. The flexible cast iron included in the boiler's construction, giving the boiler fantastic resistance to thermal shock. Combined with its installation versatility and optimal connection placements, the G215 is a boiler package that will last your home for many years to come.
Three-Pass Heat Exchanger
The three-pass heat exchanger included with the G215 allows the water to be heated three separate times, allowing a higher water temperature to be maintained throughout the system while improving heating efficiency.
Fully Thermally Insulated
The G215 boiler is encased by three inches of thermal insulation, keeping generated heat inside the boiler during downtime and preventing heat loss during uptime.
Ideal for New Installations or Renovations
The G215 boiler is ideal for both new construction and renovations of aged housing due to its adaptive heat exchanger and optimal connection placement.
Flexible Cast Iron
The heat exchanger of the Buderus G215 boiler is made of patented flexible cast iron, allowing the boiler to resist even the most punishing thermal shock.
Product Note
The boiler has an optional Logamatic R2107 that can be purchased separately as an accessory and be mounted onto the top of the boiler.
Medium MediumMedium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Oil
Combustion Type Combustion TypeCondensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production DHW ProductionDHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Staging
Mount Type
Floor
Maximum Altitude
2000 Feet
Assembly Type
Semi-Packaged
Includes Pump
No
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
86.2 %
Input Rate
1.4 GPH
DOE Heating Capacity DOE Heating CapacityAlso referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
171000 BTU
Net I=B=R Capacity Net I=B=R CapacityI=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
149000 BTU
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
6 Inches
Supply Connection
1 1/2 Inches
Return Connection
1 1/2 Inches
Certifications
IBR Listed
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
Lifetime Years
General Information
Product Line
G215
Product Category
Boiler
Medium MediumMedium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Oil
Combustion Type Combustion TypeCondensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production DHW ProductionDHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Staging
Mount Type
Floor
Maximum Altitude
2000 Feet
Assembly Type
Semi-Packaged
Includes Pump
Included with Burner Kit
Burner Model
Sold Separately
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
86.2 %
Input Rate
1.4 GPH
DOE Heating Capacity DOE Heating CapacityAlso referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
171000 BTU
Net I=B=R Capacity Net I=B=R CapacityI=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
149000 BTU
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
6 Inches
Supply Connection
1 1/2 Inches
Return Connection
1 1/2 Inches
Product Height
34 1/2 Inches
Product Width
23 1/2 Inches
Product Depth
31 Inches
Product Weight
500 Pounds
Certifications
IBR Listed
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
1 Year
Heat Exchanger Warranty
Lifetime Years
Overview
Product Category
Boiler
General Information
Product Line
G215
Product Category
Boiler
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Performance
Maximum Input Capacity Maximum Input CapacityThe Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
196000 BTU
Input Rate
1.4 GPH
Dimensions
Product Weight
15 Pounds
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
5 Years
Overview
Product Category
Boiler
Reviews
Reviews
Do You Own This Product?
Give us your opinion on this product and help any future buyer's make an informed decision.
+Thank You For Submitting Your QuestionYour submission has been sent successfully. Please give our product specialists up to two business days to respond.
Continue Shopping
×
Buderus G215/4 - 171K BTU - 86.2% AFUE - Hot Water Oil Boiler - Chimney Vent - Includes Beckett AFG Burner