Burnham Series 2 - 232k BTU - 84% AFUE - Hot Water Gas Boiler - Chimney Vent

Model: 209EN-T0 Item Number: 102577
Burnham 209EN-T0
PREVIOUS
NEXT
Burnham 209EN-T0
Enlarge Image
Our Price: $5,237.00
synchrony card icon
$66 / Month
With our 132 months 9.99% APR*
132 fixed monthly payments required.
Factory-Direct
Ships in 7-14 Business Days
Burnham Series 2 - 232k BTU - 84% AFUE - Hot Water Gas Boiler - Chimney Vent
Burnham Series 2 - 232k BTU - 84% AFUE - Hot Water Gas Boiler - Chimney Vent Model: 209EN-T0 Item Number: 102577
$5,237.00
Factory-Direct
-
+
Accessories
Features
Specifications
Reviews
Product Q&A
Manuals
Shipping Crate Icon
Free Shipping Learn More
Free Shipping
*This product qualifies for Free Shipping anywhere in the contiguous US. Accessories may ship separately. Items over 100lbs shipped via semi-truck, be sure to select "Lift Gate" to lower the product to the ground curbside. Remote area surcharges map apply, see our full shipping policy for more details.
Truck Icon
Free Lift Gate Learn More
Free Lift Gate
*This product qualifies for Free Lift Gate Service. Items over 100lbs normally ship via semi-truck. Select this service if you need the product lowered to the ground curbside. To learn more about Lift Gate Service, read our shipping policy.
Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Product Category
    Boiler
    UPC
    672616786403
DOE Heating Capacity (BTU/Hr)
Select Attribute
Pump Manufacturer
Select Attribute
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features
View More

Features

Overview for Burnham 209EN-T0

The Burnham Series 2 boiler is a well-made and reliable cast iron water boiler. Because it's made in the USA, you know you are getting quality product that will last. The Series 2 comes equipped with a circulator - your choice between a Taco or Grundfos. Another added feature is a pre-installed low water cut off, protecting your boiler from damage if the water level gets too low. Popular for direct replacements, the Series 2 offers industry standard tapping locations for easy compatibility and replacement for your existing boiler.
  • Fully Featured
  • The Burnham Series 2 comes fully featured with a Taco circulator and pre-installed low water cut off (LWCO). A LWCO is vital, preventing damage or even an explosion in the event of low water levels in your boiler
  • Durable Construction
  • An American-made cast iron heat exchanger, insulated, powder coated steel jacket, and 1" of heavy gauge insulation all contribute to the longevity of the Series 2.
  • Integrated Controls
  • Concealed within the boiler jacket, an integrated boiler control with a self-diagnostic control system give you a digital readout for status and errors.
  • Thermal Purge
  • Save energy with the thermal purge feature. The Series 2 circulates residual heating water before burning fuel.
  • Simple Venting
  • A draft hood and vent damper are included with your Series 2 boiler. These components ensure safe venting and efficient combustion.
  • Product Includes
  • (1) Burnham 209EN-T0 Hot Water Gas Boiler
  • (1) Taco Circulator
  • (1) Burnham 8" Vent Damper
  • (1) Burnham Draft Hood
  • Specifications
    View More

    Specifications

    Overview
    Product Category
    Boiler
    UPC
    672616786403
    General Information
    Product Line
    Series 2
    Product Category
    Boiler
    Medium Learn More
    Medium
    Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
    Hot Water
    Heat Exchanger Material
    Cast Iron
    Fuel Type Learn More
    Fuel Type
    To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
    Natural Gas
    Combustion Type Learn More
    Combustion Type
    Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
    Conventional
    Vent Type Learn More
    Vent Type
    Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
    Chimney Vent
    DHW Production Learn More
    DHW Production
    DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
    No
    Modulating/Staging Learn More
    Modulating/Staging
    Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
    Staging
    Mount Type
    Floor
    Minimum Altitude
    0 Feet
    Maximum Altitude
    2000 Feet
    Assembly Type
    Packaged
    Includes Pump
    Yes
    Performance
    AFUE Learn More
    AFUE
    AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
    84 %
    Maximum Input Capacity Learn More
    Maximum Input Capacity
    The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
    276000 BTU
    DOE Heating Capacity Learn More
    DOE Heating Capacity
    Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
    232000 BTU
    Net I=B=R Capacity Learn More
    Net I=B=R Capacity
    I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
    202000 BTU
    Ultra Low NOx Emissions Learn More
    Ultra Low NOx Emissions
    NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
    No
    Electrical Data
    Voltage
    120 Volts
    Phase
    1
    Frequency
    60 Hz
    Dimensions
    Flue Connection Size
    8 Inches
    Gas Connection Size
    3/4 Inch
    Supply Connection
    1 1/4 Inches
    Return Connection
    1 1/4 Inches
    Product Height
    32 1/2 Inches
    Product Width
    31 Inches
    Product Depth
    27 Inches
    Shipping Weight
    548 Pounds
    Certifications
    ETL Listed
    Yes
    ASME Certified
    Yes
    AHRI Certified
    Yes
    AHRI Reference Number
    202901887
    Warranty Information
    Parts Warranty Show ACW Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
    1 Year
    Heat Exchanger Warranty
    10 Years
    Reviews
    View More

    Reviews

    Do You Own This Product?

    Give us your opinion on this product and help any future buyer's make an informed decision.

    Product Q&A
    View More

    Product Q&A

    Be the first to ask a question.

    Whether it's a general or technical question ACWholesalers can help. Our customer service team is backed by years of experience so you can have confidence knowing that you'll be getting an insightful response.

    Manuals
    View More
     
    Share
    ×
    Burnham Series 2 - 232k BTU - 84% AFUE - Hot Water Gas Boiler - Chimney Vent
    Burnham 209EN-T0
    Loading
    ×
    Customer Review Images
    Loading
    Scroll Up ArrowTo Top