Burnham V8H - 120K BTU - 86% AFUE - Hot Water Oil Boiler - Chimney Vent

Model: CKV8H3WEC-LLWFH Item Number: 150661
Burnham CKV8H3WEC-LLWFH
PREVIOUS
NEXT
Burnham CKV8H3WEC-LLWFH
Enlarge Image
Product Discontinued
Sorry, this product is no longer available.
Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Product Line
    V8H
    Product Category
    Boiler
    Medium
    Hot Water
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features
View More

Features

Overview for Burnham CKV8H3WEC-LLWFH

The Burnham V8H has been the standard to beat for cast iron oil-fired boilers. It has a tried-and-true design that combines a durable cast iron heat exchanger with top-notch components, which makes it a top choice for homeowners. The V8H is a dependable replacement for countless households and its installation is simple and affordable. If space is an issue, the V8H can also come with a tankless hot water heating coil. Experts in the heating industry trust the V8H to deliver years of cozy and fuss-free warmth to their clients, offering exceptional value for your household.
  • Efficiency
  • The V8H oil-fired water boiler is exceptionally efficient with 86.6% AFUE rating, using less fuel to generate the same heat, saving on energy costs and reducing carbon footprint.
  • Versatility
  • This boiler is designed to be highly versatile, with a range of sizes and configurations available to suit any home heating needs. The V8H can be used with traditional radiator systems, radiant floor heating, and even snow melting systems.
  • Durability
  • This boiler is built to last, with a rugged cast-iron heat exchanger and stainless steel burners that are built to withstand the rigors of daily use. Additionally, the V8H features a compact design that allows for easy installation and maintenance.
  • Safety
  • The V8H is designed with safety in mind, featuring multiple safety mechanisms such as a low-water cutoff, high-limit safety switch, and pressure relief valve. These features help to protect the boiler and your home from potential damage or accidents.
  • Product Note
    This boiler does not include an oil burner or circulator pump. Please see the Accessories tab for compatible burners if you require one.
    Specifications
    View More

    Specifications

    General Information
    Product Line
    V8H
    Product Category
    Boiler
    Medium Learn More
    Medium
    Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
    Hot Water
    Heat Exchanger Material
    Cast Iron
    Fuel Type Learn More
    Fuel Type
    To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
    Oil
    Combustion Type Learn More
    Combustion Type
    Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
    Conventional
    Vent Type Learn More
    Vent Type
    Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
    Chimney Vent
    DHW Production Learn More
    DHW Production
    DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
    No
    Modulating/Staging Learn More
    Modulating/Staging
    Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
    Staging
    Mount Type
    Floor
    Includes Pump
    No
    Assembly Type
    Knockdown
    Burner Model
    Sold Separately
    UPC
    672616837907
    Performance
    AFUE Learn More
    AFUE
    AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
    86 %
    Input Rate
    1 GPH
    DOE Heating Capacity Learn More
    DOE Heating Capacity
    Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
    120 BTU
    Net I=B=R Capacity Learn More
    Net I=B=R Capacity
    I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
    104 BTU
    Ultra Low NOx Emissions Learn More
    Ultra Low NOx Emissions
    NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
    No
    Electrical Data
    Voltage
    120 Volts
    Phase
    1
    Frequency
    60 Hz
    Dimensions
    Flue Connection Size
    6 Inches
    Supply Connection
    1 1/2 Inches
    Return Connection
    1 1/2 Inches
    Product Height
    32 1/4 Inches
    Product Width
    24 Inches
    Product Depth
    17 1/8 Inches
    Shipping Weight
    534 Pounds
    Certifications
    Country of Origin
    United States
    ETL Listed
    Yes
    Energy Star Listed
    No
    ASME Certified
    Yes
    AHRI Certified
    Yes
    AHRI Reference Number
    205151645
    Warranty Information
    Parts Warranty Show ACW Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
    1 Year
    Heat Exchanger Warranty
    Limited Lifetime Years
    Reviews
    View More

    Reviews

    Do You Own This Product?

    Give us your opinion on this product and help any future buyer's make an informed decision.

    Manuals
    View More
    Share
    ×
    Burnham V8H - 120K BTU - 86% AFUE - Hot Water Oil Boiler - Chimney Vent
    Burnham CKV8H3WEC-LLWFH
    Loading
    ×
    Customer Review Images
    Loading
    Scroll Up ArrowTo Top