Daikin - 30k BTU Cooling + Heating - Wall Mounted Air Conditioning System - 15.9 SEER

Model: FTX36NVJU-RX36NMVJU Item Number: 88959
Daikin FTX36NVJU-RX36NMVJU
PREVIOUS
NEXT
Daikin FTX36NVJU-RX36NMVJU
Daikin FTX36NVJU-RX36NMVJU
Daikin FTX36NVJU-RX36NMVJU
Daikin FTX36NVJU-RX36NMVJU
Daikin FTX36NVJU-RX36NMVJU
Enlarge Image
Daikin FTX36NVJU-RX36NMVJU
Daikin FTX36NVJU-RX36NMVJU
Watch Video
Daikin FTX36NVJU-RX36NMVJU
Watch Video
Daikin FTX36NVJU-RX36NMVJU
Watch Video
Daikin FTX36NVJU-RX36NMVJU
Watch Video
Daikin FTX36NVJU-RX36NMVJU
Watch Video
Daikin FTX36NVJU-RX36NMVJU
Watch Video
Daikin FTX36NVJU-RX36NMVJU
Daikin FTX36NVJU-RX36NMVJU
Daikin FTX36NVJU-RX36NMVJU
Daikin FTX36NVJU-RX36NMVJU
View All
Product Discontinued
Sorry, this product is no longer available.
Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Weight
    171 Pounds Learn More
    171 Pounds
    Total weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
    Type
    Wall Mounted
    Operating Mode
    Heating and Cooling
Bundle Includes 2 items
  • product image
    (1) Daikin 36,000 BTU 15.9 SEER Ductless Heat Pump Condenser (RX36NMVJU)
  • product image
    (1) Daikin 36,000 BTU Ductless Wall Mounted Air Conditioner Air Handler (FTX36NVJU)
Features & Bundle Details
View More

Features & Bundle Details

Overview for Daikin FTX36NVJU-RX36NMVJU

Overview for Daikin FTX36NVJU-RX36NMVJU

Daikin's 15.9 SEER single split systems feature streamlined, wallmounted indoor units paired with quietly compact outdoor units. With a flexible design made to blend in discreetly with any home design, these systems are ideal for single room enhancements and additions. Designed for absolute comfort, Daikins units include features to ensure a comfortable experience every moment. From the wide angle louver design to the autoswing and comfortable mode controller settings, effective heating and cooling is ensured throughout the space.
Bundle Includes 2 items
Specifications
View More

Specifications

Included In This Bundle

Bundle Overviewgrey arrow icon
General Information
Type
Wall Mounted
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Number of Zones Learn More
Number of Zones
A zone is a room or area within a building that has its own temperature control.
1
Refrigerant Type
R-410A
Indoor Unit Size(s) Learn More
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
36
Outdoor Unit Size
36000 BTU
DOE Regional Compliance Learn More
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
Nationwide
Line Set Size
1/4" x 5/8"
Performance
Cooling BTU
36000
Cooling Capacity
36000 BTU
Heating Capacity
36000 BTU
SEER Learn More
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system.
15.9
EER Learn More
EER
EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system.
9.1
HSPF Learn More
HSPF
HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system.
9.2
Low Ambient Heating
No
Minimum Outdoor Temperature for Heating Learn More
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures.
5 F
Minimum Outdoor Temperature for Cooling
-4 F
Dimensions
Product Weight
171 Pounds
Shipping Weight
186 Pounds
General Information
Type
Outdoor Condenser
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Number of Zones Learn More
Number of Zones
A zone is a room or area within a building that has its own temperature control.
1
Refrigerant Type
R-410A
Indoor Unit Size(s) Learn More
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
36
Installation Location
Indoor
Line Set Size
1/4" x 5/8"
Performance
Cooling BTU
36000
Cooling Capacity
36000 BTU
Heating Capacity
36000 BTU
SEER Learn More
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system.
17.5
EER Learn More
EER
EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system.
9.8
HSPF Learn More
HSPF
HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system.
9.3
Low Ambient Heating
No
Minimum Outdoor Temperature for Heating Learn More
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures.
5 F
Minimum Outdoor Temperature for Cooling
50 F
Electrical Data
Voltage
208/230 Volts
Dimensions
Product Weight
133 Pounds
Shipping Weight
143 Pounds
General Information
Type
Wall Mounted
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Number of Zones Learn More
Number of Zones
A zone is a room or area within a building that has its own temperature control.
1
Refrigerant Type
R-410A
Indoor Unit Size(s) Learn More
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
36
Line Set Size
1/4" x 5/8"
Performance
Cooling BTU
36000
Cooling Capacity
36000 BTU
Heating Capacity
36000 BTU
SEER Learn More
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system.
15.9
EER Learn More
EER
EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system.
9.1
HSPF Learn More
HSPF
HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system.
9.2
Low Ambient Heating
No
Minimum Outdoor Temperature for Heating Learn More
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures.
5 F
Minimum Outdoor Temperature for Cooling
-4 F
Dimensions
Product Weight
38 Pounds
Shipping Weight
43 Pounds
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
5 Years
Reviews
View More

Reviews

Do You Own This Product?

Give us your opinion on this product and help any future buyer's make an informed decision.

 
Share
×
Daikin - 30k BTU Cooling + Heating - Wall Mounted Air Conditioning System - 15.9 SEER
Daikin FTX36NVJU-RX36NMVJU
Loading
Daikin FTX36NVJU-RX36NMVJU
Daikin FTX36NVJU-RX36NMVJU
Watch Video
Daikin FTX36NVJU-RX36NMVJU
Watch Video
Daikin FTX36NVJU-RX36NMVJU
Watch Video
Daikin FTX36NVJU-RX36NMVJU
Watch Video
Daikin FTX36NVJU-RX36NMVJU
Watch Video
Daikin FTX36NVJU-RX36NMVJU
Watch Video
Daikin FTX36NVJU-RX36NMVJU
Daikin FTX36NVJU-RX36NMVJU
Daikin FTX36NVJU-RX36NMVJU
Daikin FTX36NVJU-RX36NMVJU
×
Customer Review Images
Loading
Scroll Up ArrowTo Top