This and many other products are now available for order online and pickup at the Power Equipment Direct warehouse in Bolingbrook, Illinois or at a Ferguson location near you.
Answer:
Your nearest pickup location within a 50-mile radius is automatically selected when you enter the site. To change your pickup location and see availability for other nearby locations, click the "Change Pickup Location" link on the product page or in the cart.
Answer:
Eligible items will have the Local Pickup option available both on the product page and in the cart. Select this option for all items you wish to pick up. Please note that Local Pickup can only be scheduled online at this time.
Answer:
Items are usually ready for pickup the same day the online order is placed, but this will depend on order volume and time of day. When your order is ready, you will receive an email including specific pickup instructions. Make sure to check your junk/spam folder. Orders not picked up within two business days may be canceled. You should opt to have your items shipped if you cannot pick them up promptly.
Answer:
During checkout, you will be prompted to enter the name, mobile phone number, and email address of the person who will be picking up the order. For your protection, only you or your designated pickup party may pick up your order. You will need your order confirmation and a government-issued photo ID to pick up your order.
Answer:
Not all items are available at all locations, so pickup availability will vary based on the selected store. Additionally, some items ship directly from our manufacturer partners and are not available for pickup. You can use the "Change Pickup Location" link to check for availability at nearby Local Pickup locations.
Answer:
Due to packaging, shipping costs, and other factors, some items cannot be shipped and are offered exclusively through Local Pickup.
Answer:
Credit/debit cards, Apple Pay, Google Pay, PayPal, and financing are accepted for Local Pickup orders.
Answer:
Make sure to have your order confirmation and a government-issued photo ID available when picking up your order. Check the item dimensions and ensure the items will fit in your vehicle. Bring any straps and other materials that will be needed to secure the items for transport.
New NewThis product is new and has never been used. It's in its original packaging, which has not been opened.
Weight
345.6 Pounds 345.6 PoundsTotal weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
Product Category
Mini Split Heat Pump System
View More
Bundle Includes 9 items
(1) GE - 36k BTU - Endure Series Outdoor Condenser - For 2-4 Zones (ASH436NCDWA)
(4) GE - 7k BTU - Endure Series Concealed Duct Unit - For Multi-Zone (AD07SL2VHB)
(4) GE - Non-Programmable Wired Controller (QACT17A)
View Full Bundle
+Share This Product
Recommended Accessories
Required AccessoriesAdd All Required
Installation Accessories
Features & Bundle Details
Features & Bundle Details
Overview for GE Mini Splits GE4L36D07070707
A common challenge for mini split systems installed in frigid environments is the ability to effectively produce heat in subzero temperatures. Enter the Endure Multi Series from GE. Including state-of-the-art mini split technology, the Endure Multi Series will produce heat down to an impressive -15° F. The concealed duct unit features the slimmest design in the industry while remaining incredibly quiet. A remote controller is included with each indoor unit for your convenience. Persevere through the frigid winter and hot summer months with the Endure Multi Series from GE.
Inverter Technology
The Endure Series features leading A-PAM DC Inverter Technology to provide efficient and quiet operation. The inverter is used to continuously regulate refrigerant flow and ensure there's no wasted energy.
Low Ambient Heating
With the ability to provide heat at ambient temperatures reaching -15° F, the Endure Series won't leave you hanging when it gets cold outside.
Quiet Operation
The Endure Series concealed duct units feature a quiet mode that operates at a sound level down to 21 dB.
Blue Fin Coating
The Endure Series outdoor unit features a special coating to whisk away condensate water, preventing rust and extending its lifespan.
Warm Start
GE's hot start technology prevents cold drafts by delaying fan operation until the heat exchanger has warmed up.
Recommended line set sizes for indoor unit connectivity:
AD07SL2VHB: 1/4" x 3/8" Line Set (Qty 4)
Built-In WiFi
Product Note
Each indoor unit will include any port adapters necessary for multi-zone installation.This product requires the following accessories for installation:
Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor units.
Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor units to drain locations of your choosing.
Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
Connecting Wire - This durable, insulated wire provides power to your indoor units from your outdoor condenser.
Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
Adding these accessories to your order will provide a complete, ready-to-install mini split system.GE products include a 10-year parts and compressor warranty with the requirement that installation is completed by a licensed contractor and that the product is registered at https://www.geappliances.com/ductless/ within 60 days of installation. All Mini Split Systems require one Primary Mini Split Installation Kit. You may also require one or more Secondary Installation Kits if you have a Multi-Zone system. You will need a Secondary Installation Kit for each additional indoor unit.
Bundle Includes 9 items
GE - 36k BTU - Endure Series Outdoor Condenser - For 2-4 Zones
Model: ASH436NCDWA
Item Number: 107800
Quantity: 1
GE - 7k BTU - Endure Series Concealed Duct Unit - For Multi-Zone
Model: AD07SL2VHB
Item Number: 107805
Quantity: 4
GE - Non-Programmable Wired Controller
Model: QACT17A
Item Number: 107815
Quantity: 4
Specifications
Specifications
Included In This Bundle
Bundle Overview
Bundle Overview
ASH436NCDWA Specifications
AD07SL2VHB Specifications
QACT17A Specifications
Overview
Product Category
Mini Split Heat Pump System
General Information
Type
Concealed Duct
Product Line
Endure Series
Product Category
Mini Split Heat Pump System
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Number of Zones Number of ZonesA zone is a room or area within a building that has its own temperature control.
4
Refrigerant Type
R-410A
Indoor Unit Size(s) Indoor Unit Size(s)Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
7 + 7 + 7 + 7
Outdoor Unit Size
36000 BTU
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
Nationwide
Performance
SEER SEERSEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system.
17.0
EER EEREER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system.
10.0
HSPF HSPFHSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system.
10.5
Cooling Power Input
2740 Watts
Heating Power Input
2710 Watts
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating Minimum Outdoor Temperature for HeatingThis is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures.
-15 F
Minimum Outdoor Temperature for Cooling
23 F
Dimensions
Product Weight
345.6 Pounds
Shipping Weight
403.8 Pounds
Certifications
ETL Listed
Yes
Energy Star Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
205782853
General Information
Type
Outdoor Condenser
Product Line
Endure Series
Product Category
Mini Split System Components
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Maximum Number of Zones
4
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Installation Location
Outdoor
Performance
Cooling BTU
36000
Maximum Sound Level Maximum Sound LevelSound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
59 dB
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating Minimum Outdoor Temperature for HeatingThis is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures.
-15 F
Minimum Outdoor Temperature for Cooling
14 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
40 Amps
Dimensions
Maximum Line Length
230 Feet
Line Set A Liquid Connection
1/4 Inch
Line Set A Gas Connection
3/8 Inch
Line Set B Liquid Connection
1/4 Inch
Line Set B Gas Connection
3/8 Inch
Line Set C Liquid Connection
1/4 Inch
Line Set C Gas Connection
3/8 Inch
Line Set D Liquid Connection
1/4 Inch
Line Set D Gas Connection
1/2 Inch
Product Height
33 1/8 Inches
Product Width
37 3/8 Inches
Product Depth
13 3/8 Inches
Product Weight
198.4 Pounds
Shipping Weight
215 Pounds
Certifications
ETL Listed
Yes
UL Listed
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
5 Years
Compressor Warranty
7 Years
Overview
Product Category
Mini Split System Components
General Information
Type
Concealed Duct
Product Line
Endure Series
Product Category
Mini Split System Components
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Indoor Unit Size(s) Indoor Unit Size(s)Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
7
Installation Location
Indoor
Performance
Cooling BTU
7000
Cooling Capacity
7000 BTU
Maximum Air Flow
353 CFM
Minimum Air Flow
188 CFM
Minimum Sound Level
21 dB
Maximum Sound Level Maximum Sound LevelSound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
35 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
1/4 Inch
Liquid Connection Size
3/8 Inch
Product Height
7 1/2 Inches
Product Width
33 1/2 Inches
Product Depth
16 1/2 Inches
Product Weight
36.8 Pounds
Shipping Weight
47.2 Pounds
Certifications
ETL Listed
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
5 Years
Overview
Product Category
Mini Split System Components
General Information
Type
Wired Remote
Product Line
Endure Series
Product Category
Mini Split Accessories
Overview
Product Category
Mini Split Accessories
Reviews
Reviews
Do You Own This Product?
Give us your opinion on this product and help any future buyer's make an informed decision.
+Thank You For Submitting Your QuestionYour submission has been sent successfully. Please give our product specialists up to two business days to respond.