Goodman 80% AFUE 80,000 BTU 2 Stage Upflow/Horizontal Gas Furnace

Model: GMEC800803BN Item Number: 100081
Goodman GMEC800803BN
PREVIOUS
NEXT
Goodman GMEC800803BN
Enlarge Image
Product Discontinued
Sorry, this product is no longer available.
Try This Instead
View Goodman GM9C80 - 80k BTU - Gas Furnace - 80% AFUE
Model: 
GM9C800803BN
214 In-Stock
Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Weight
    118 Pounds Learn More
    118 Pounds
    Total weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
    Type
    Gas Furnace
    Product Line
    GMEC80
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features
View More

Features

Overview for Goodman GMEC800803BN

The GMEC80 two-stage, multi-speed furnace was designed to provide premium efficiency at an affordable price. The GMEC80 utilizes Goodman's superior heat exchanger design to provide efficient, reliable heating and ensure that your energy dollars aren't being vented out of your home. Instead of a standard multi-speed blower motor, the GMEC80 utilizes an ECM motor, which uses less power and provides smarter circulation. The value doesn't end at efficiency, the GMEC80 features many different connection options to reduce installation time and a self-diagnosing control board to expedite maintenance. If you're looking to cut your energy bills and improve your comfort without breaking the bank, your search stops with the GMEC80.
  • Advanced Heat Exchanger Design
  • The GMEC80 furnace employs a reliable heavy-duty tubular heat exchanger design. Aluminized steel is used in construction for incredibly efficient heat transfer and wrinkle-bend technology for extraordinary durability.
  • Multi-Speed ECM Motor
  • The GMEC80's energy efficient blower motor uses the lowest speed it can to deliver precise temperature control for your home while keeping utility bills to a minimum.
  • Quiet Comfort
  • Goodman takes great pride in producing equipment that doesn't disrupt your home. The blower and gas valve of the GMEC80 were selected for their incredibly low sound levels.
  • Secure Cabinet
  • All GMEC80 furnaces are protected by a durable steel cabinet rated for less than 2% air leakage. The heat exchanger section is insulated to prevent heat loss and the return side of the cabinet is solid and airtight.
  • Self-Diagnostic Control Board
  • The GMEC80 continuously monitors the system to ensure reliable operation, stores the last diagnostic codes in memory, and a flashing LED indicates condition for quick troubleshooting.
  • Extended Warranty
  • Goodman offers a 10-year limited unit replacement and parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See the "Manuals" tab for more information.
  • Specifications
    View More

    Specifications

    General Information
    Type
    Gas Furnace
    Product Line
    GMEC80
    Fuel Type Learn More
    Fuel Type
    To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
    Natural Gas
    Vent Type Learn More
    Vent Type
    Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
    Chimney Vent
    Modulating/Staging Learn More
    Modulating/Staging
    Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
    Two Stage
    Blower Motor Type
    ECM Multi-Speed
    Configuration Learn More
    Configuration
    Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
    Upflow/Horizontal
    Gas Conversion Kit
    Available
    DOE Regional Compliance Learn More
    DOE Regional Compliance
    In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
    Nationwide (Except CA)
    UPC
    663051590335
    Performance
    AFUE Learn More
    AFUE
    AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
    80 %
    Heating BTU
    80000
    High Fire Input
    80000 BTU
    High Fire Output
    64000 BTU
    Low Fire Input
    56000 BTU
    Low Fire Output
    44800 BTU
    Maximum Air Flow
    1200 CFM
    Ultra Low NOx Emissions Learn More
    Ultra Low NOx Emissions
    NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
    No
    Low NOx Emissions Learn More
    Low NOx Emissions
    NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx.
    No
    Electrical Data
    Voltage
    115 Volts
    Phase
    1
    Frequency
    60 Hz
    Minimum Circuit Ampacity
    8.7 Amps
    Recommended Breaker Size
    15 Amps
    Dimensions
    Flue Connection Size
    4 Inches
    Cabinet Width
    17 1/2 Inches
    Product Height
    33 1/2 Inches
    Product Width
    17 1/2 Inches
    Product Depth
    28 Inches
    Product Weight
    118 Pounds
    Shipping Weight
    118 Pounds
    Certifications
    ETL Listed
    Yes
    AHRI Certified
    Yes
    ISO Certified
    Yes
    AHRI Reference Number
    203692607
    Warranty Information
    Parts Warranty Show ACW Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
    10 Years
    Heat Exchanger Warranty
    Lifetime Years
    Reviews
    View More

    Reviews

    Do You Own This Product?

    Give us your opinion on this product and help any future buyer's make an informed decision.

    Manuals
    View More
    Share
    ×
    Goodman 80% AFUE 80,000 BTU 2 Stage Upflow/Horizontal Gas Furnace
    Goodman GMEC800803BN
    Loading
    ×
    Customer Review Images
    Loading
    Scroll Up ArrowTo Top