This and many other products are now available for order online and pickup at the Power Equipment Direct warehouse in Bolingbrook, Illinois or at a Ferguson location near you.
Answer:
Your nearest pickup location within a 50-mile radius is automatically selected when you enter the site. To change your pickup location and see availability for other nearby locations, click the "Change Pickup Location" link on the product page or in the cart.
Answer:
Eligible items will have the Local Pickup option available both on the product page and in the cart. Select this option for all items you wish to pick up. Please note that Local Pickup can only be scheduled online at this time.
Answer:
Items are usually ready for pickup the same day the online order is placed, but this will depend on order volume and time of day. When your order is ready, you will receive an email including specific pickup instructions. Make sure to check your junk/spam folder. Orders not picked up within two business days may be canceled. You should opt to have your items shipped if you cannot pick them up promptly.
Answer:
During checkout, you will be prompted to enter the name, mobile phone number, and email address of the person who will be picking up the order. For your protection, only you or your designated pickup party may pick up your order. You will need your order confirmation and a government-issued photo ID to pick up your order.
Answer:
Not all items are available at all locations, so pickup availability will vary based on the selected store. Additionally, some items ship directly from our manufacturer partners and are not available for pickup. You can use the "Change Pickup Location" link to check for availability at nearby Local Pickup locations.
Answer:
Due to packaging, shipping costs, and other factors, some items cannot be shipped and are offered exclusively through Local Pickup.
Answer:
Credit/debit cards, Apple Pay, Google Pay, PayPal, and financing are accepted for Local Pickup orders.
Answer:
Make sure to have your order confirmation and a government-issued photo ID available when picking up your order. Check the item dimensions and ensure the items will fit in your vehicle. Bring any straps and other materials that will be needed to secure the items for transport.
NewNewThis product is new and has never been used. It's in its original packaging, which has not been opened.
Weight
545 Pounds545 PoundsTotal weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
Product Category
Furnace & Heat Pump Package
View More
Bundle Includes 4 items
(1) Goodman 5 Ton 16 SEER Heat Pump Air Conditioner Condenser (GSZC160601)
A Goodman high efficiency heat pump and furnace package is the perfect way to upgrade your home's HVAC system. This kit contains a GSZC two-stage heat pump with an advanced coil design to maximize efficiency. The heat pump is paired with a GCVC furnace equipped with an ECM variable speed motor. This pair was specifically chosen to provide efficient comfort year round. A cased coil and valve kit are included, making this kit an affordable, efficient, whole home solution.
Quiet Comfort
The wire fan discharge grille and condenser fan motor of the GSZC line were designed to reduce noise levels without compromising performance. This model also has a high-capacity discharge muffler and a high-density foam sound blanket.
SmartShift
Goodman's SmartShift technology, combined with ambient and coil temperature sensors, gives this unit a quiet and effective defrost system. SmartShift also helps to prevent short-cycling, increasing the efficiency of defrost operations.
UltraTech Compressor
A two-stage Copeland UltraTech scroll compressor provides the GSZC with incredibly reliable refrigerant flow. The second stage increases efficiency by allowing the compressor to operate at a lower capacity when your demand is low.
All-Aluminum Coil
Goodman's evaporator coils use a reliable all-aluminum design featuring sine fins and grooved tubes. This design maximizes surface area and optimizes heat transfer for efficient comfort.
Condensate Management
The CAPF features foil-faced insulation to inhibit the formation of condensate and a rust-resistant thermoplastic drain pan to capture what does form, keeping your system safe and operational.
Advanced Heat Exchanger Design
The GCVC furnace employs a dual-diameter tubular heat exchanger design. Aluminized steel is used in construction for efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance dependability and longevity.
Secondary Heat Exchanger
This furnace produces additional heat without using more fuel by directing combustion gases through a secondary heat exchanger before they are vented. To prevent damage, this secondary heat exchanger is made of corrosion-resistant stainless steel.
Variable Speed ECM Motor
The GCVC line features a variable speed ECM motor. Variable speed motors allow the furnace to operate at higher efficiencies than multi-speed blowers by controlling the speed of the blower based on heating demands.
Extended Warranty
Goodman offers a 10-year limited parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See warranty sheet under the "Manuals" tab for more information.
Product Note
The recommended line set size for this system will vary based on the length of line set you require for installation. Compatible line sets can be found under the "Recommended Accessories" tab. NOTE: Due to DOE regulations, as of January 1st this unit can no longer be installed in the southwest and southeast DOE regions.
Bundle Includes 4 items
Goodman 5 Ton 16 SEER Heat Pump Air Conditioner Condenser
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Two Stage
Blower Motor Type
ECM Variable-Speed
Coil Width
21 Inches
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
Nationwide (Except CA)
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
96 %
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
5.0 Tons
Cooling Capacity
54000 BTU
Nominal Cooling Capacity
60000 BTU
Heating BTU
100000
SEER SEERSEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system.
16.0
EER EEREER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system.
12.5
HSPF HSPFHSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system.
9.2
Maximum Air Flow
1520 CFM
Dimensions
Product Weight
545 Pounds
Shipping Weight
559 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
202148739
General Information
Type
Heat Pump Condenser
Product Line
GSZC16
Product Category
Heat Pump
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Refrigerant Type
R-410A
Installation Location
Outdoor
Compressor Stages Compressor StagesStages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single Stage
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
Nationwide
Installation Available
Yes
Performance
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
5.0 Tons
Cooling BTU
60000
Cooling Capacity
60000 BTU
SEER SEERSEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system.
16.0
Maximum Sound Level Maximum Sound LevelSound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
75 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
31 Amps
Recommended Breaker Size
50 Amps
Dimensions
Suction Connection Size
1 1/8 Inches
Liquid Connection Size
3/8 Inch
Product Height
38 1/4 Inches
Product Width
35 1/2 Inches
Product Depth
35 1/2 Inches
Product Weight
313 Pounds
Shipping Weight
339 Pounds
Certifications
ETL Listed
Yes
Energy Star Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
Limited* 10 Years Years
Compressor Warranty
LIFETIME Years
Overview
Product Category
Heat Pump
General Information
Type
Gas Furnace
Product Line
GCVC96
Product Category
Furnace
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Two Stage
Blower Motor Type
ECM Variable-Speed
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow/Horizontal
Gas Conversion Kit
Available
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
Nationwide (Except CA)
Installation Available
Yes
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
96 %
Heating BTU
100000
High Fire Input
100000 BTU
High Fire Output
96000 BTU
Low Fire Input
70000 BTU
Low Fire Output
67200 BTU
Maximum Air Flow
2000 CFM
Ultra Low NOx Emissions Ultra Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
No
Low NOx Emissions Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx.
Yes
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
14.4 Amps
Recommended Breaker Size
20 Amps
Dimensions
Flue Connection Size
2 or 3 Inches
Cabinet Width
21 Inches
Product Height
34 1/2 Inches
Product Width
21 Inches
Product Depth
28 3/4 Inches
Product Weight
145 Pounds
Shipping Weight
145 Pounds
Certifications
ETL Listed
Yes
Energy Star Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
7368844
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
5 Years
Heat Exchanger Warranty
20 Years
Overview
Product Category
Furnace
General Information
Type
Evaporator Coil
Product Line
CAPF
Product Category
Evaporator Coil
Refrigerant Type
R-410A
Casing
Cased
Style
A Coil
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Downflow
Installation Available
Yes
TXV Installed
No
Performance
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
4.0 - 5.0 Tons
Cooling BTU
60000
Nominal Minimum Cooling Capacity
48000 BTU
Dimensions
Suction Connection Size
7/8 Inch
Liquid Connection Size
3/8 Inch
Cabinet Width
21 Inches
Product Height
30 Inches
Product Width
21 Inches
Product Depth
21 Inches
Product Weight
73 Pounds
Shipping Weight
83 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Warranty WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab.
5 Years
Overview
Product Category
Evaporator Coil
General Information
Type
TXV Kit
Product Line
TX
Product Category
Forced Air Accessories
Refrigerant Type
R-410A
Dimensions
Product Weight
1 Pound
Shipping Weight
2 Pounds
Overview
Product Category
Forced Air Accessories
Reviews
Reviews
Do You Own This Product?
Give us your opinion on this product and help any future buyer's make an informed decision.
+Thank You For Submitting Your QuestionYour submission has been sent successfully. Please give our product specialists up to two business days to respond.