LG 21,000 BTU 21.7 SEER Recessed Tri Zone Heat Pump System 7+7+7

Model: LMU24CHV 3-LMCN078HV-NG Item Number: 87718
LG LMU24CHV 3-LMCN078HV-NG
PREVIOUS
NEXT
LG LMU24CHV 3-LMCN078HV-NG
LG LMU24CHV 3-LMCN078HV-NG
LG LMU24CHV 3-LMCN078HV-NG
LG LMU24CHV 3-LMCN078HV-NG
LG LMU24CHV 3-LMCN078HV-NG
Enlarge Image
LG LMU24CHV 3-LMCN078HV-NG
LG LMU24CHV 3-LMCN078HV-NG
LG LMU24CHV 3-LMCN078HV-NG
LG LMU24CHV 3-LMCN078HV-NG
LG LMU24CHV 3-LMCN078HV-NG
View All
Product Discontinued
Sorry, this product is no longer available.
Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Weight
    100 Pounds Learn More
    100 Pounds
    Total weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
    Type
    Ceiling Cassette
    Operating Mode
    Heating and Cooling
Bundle Includes 4 items
  • product image
    (1) LG 24,000 BTU Ductless Multi Zone Heat Pump Air Conditioner Condenser (LMU24CHV)
  • product image
    (3) LG 7,000 BTU Ceiling Cassette For Multi-Zone w/o Grille (LMCN078HV-NG)
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features & Bundle Details
View More

Features & Bundle Details

Overview for LG LMU24CHV 3-LMCN078HV-NG

Overview for LG LMU24CHV 3-LMCN077HVLG Ceiling Cassette Air Conditioning Systems offer convenient solutions that are cost-effective. These innovative systems are split into two efficient units. The Ceiling-Cassette interior unit Features four-way controlled louvers and choice of fan speeds to provide the necessary air distribution. The larger, Flex Multi-Split systems operate two, three or four interior units that are mounted in separate rooms. Each indoor unit comes with its own remote control, allowing the customer to set the temperature individually in different rooms. These units are connected to a single exterior unit. The interior units are available in a variety of styles, including Art Cool, Standard, Ceiling Cassette, and Ceiling Concealed Duct models. Dual-,Tri- and Quad-Zone are Heat Pump systems.
Bundle Includes 4 items
  • product kit image
    LG 24,000 BTU Ductless Multi Zone Heat Pump Air Conditioner Condenser
    Model: LMU24CHV
    Item Number: 50832
    Quantity: 1
  • product kit image
    LG 7,000 BTU Ceiling Cassette For Multi-Zone w/o Grille
    Model: LMCN078HV-NG
    Item Number: 95029
    Quantity: 3
Specifications
View More

Specifications

Included In This Bundle

Bundle Overviewgrey arrow icon
General Information
Type
Ceiling Cassette
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Number of Zones Learn More
Number of Zones
A zone is a room or area within a building that has its own temperature control.
3
Refrigerant Type
R-410A
Indoor Unit Size(s) Learn More
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
7 + 7 + 7
Outdoor Unit Size
24000 BTU
DOE Regional Compliance Learn More
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
Nationwide
Performance
SEER Learn More
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system.
21.7
Cooling Power Input
1.48 Watts
Heating Power Input
1.8 Watts
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating Learn More
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures.
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Dimensions
Product Weight
100 Pounds
Shipping Weight
108 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
General Information
Type
Outdoor Condenser
Product Line
Multi F
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Maximum Number of Zones
3
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Installation Location
Outdoor
Performance
Cooling BTU
24000
Maximum Sound Level Learn More
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
52 dB
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating Learn More
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures.
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
20 Amps
Dimensions
Maximum Line Length
246.1 Feet
Line Set A Liquid Connection
1/4 Inch
Line Set A Gas Connection
3/8 Inch
Line Set B Liquid Connection
1/4 Inch
Line Set B Gas Connection
3/8 Inch
Line Set C Liquid Connection
1/4 Inch
Line Set C Gas Connection
3/8 Inch
Product Height
25 19/24 Inches
Product Width
34 1/4 Inches
Product Depth
12 29/48 Inches
Product Weight
100 Pounds
Shipping Weight
108 Pounds
Certifications
ETL Listed
Yes
UL Listed
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
5 Years
Compressor Warranty
7 Years
General Information
Type
Ceiling Cassette
Product Line
Multi F
Product Sub-line
Four-Way Ceiling Cassette
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Remote Control
Wireless
Indoor Unit Size(s) Learn More
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
7
Installation Location
Indoor
Grille
Not Included
Required Grille Model
PT-UQC
Performance
Cooling BTU
7000
Cooling Capacity
7000 BTU
Maximum Air Flow
265 CFM
Minimum Air Flow
177 CFM
Minimum Sound Level
24 dB
Maximum Sound Level Learn More
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
31 dB
Electrical Data
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
8 7/16 Inches
Product Width
22 7/16 Inches
Product Depth
22 7/16 Inches
Product Weight
26 Pounds
Shipping Weight
31 Pounds
Certifications
UL Listed
Yes
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
5 Years
Reviews
View More

Reviews

Do You Own This Product?

Give us your opinion on this product and help any future buyer's make an informed decision.

Manuals
View More
 
Share
×
LG 21,000 BTU 21.7 SEER Recessed Tri Zone Heat Pump System 7+7+7
LG LMU24CHV 3-LMCN078HV-NG
Loading
LG LMU24CHV 3-LMCN078HV-NG
LG LMU24CHV 3-LMCN078HV-NG
LG LMU24CHV 3-LMCN078HV-NG
LG LMU24CHV 3-LMCN078HV-NG
LG LMU24CHV 3-LMCN078HV-NG
×
Customer Review Images
Loading
Scroll Up ArrowTo Top