Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Weight
    154 Pounds Learn More
    154 Pounds
    Total weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
    Product Category
    Mini Split Heat Pump System
Bundle Includes 2 items
  • product image
    (1) LG - 18k BTU - High-Efficiency Outdoor Condenser - Single Zone Only (LSU181HSV5)
  • product image
    (1) LG 18k BTU Wall Mounted Unit - For Multi or Single-Zone (LSN181HSV5)
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features & Bundle Details
View More

Features & Bundle Details

Overview for LG LS181HSV5

LG's devotion to providing efficient ductless solutions can be seen across their entire catalog. The High Efficiency lineup of ductless heat pump systems support high SEER2 ratings, low sound levels, and robust functionality for heating and cooling nearly any space. The LS181HSV5 brings you 22.0 SEER2 operations with indoor sound levels as low as 31 dB. This system also makes it easy to stay comfortable thanks to several automatic operation modes that may be set with the system's convenient wireless handheld remote controller. An easy installation process rounds out this system, which makes a great addition to nearly any home.
  • Inverter Technology
  • An electronic expansion valve and a variable speed condenser compressor carefully regulate the refrigerant flow, reducing energy consumption and allowing for consistent, accurate temperatures without overshooting or short-cycling.
  • Gold Fin Protection
  • To ensure the reliability and longevity of the LSU181HSV5's heat exchanger, LG employs a Gold Fin coating that prevents corrosion and improves durability.
  • Quiet Design
  • The LSN181HSV5 indoor unit features a cross flow fan that restricts the pressure of air flow and lowers sound levels. Both the outdoor and indoor units enjoy reduced electrical and mechanical sound thanks to their brushless direct current fan motors.
  • Self-Cleaning Coil
  • The LSN181HSV5 indoor unit features a self-cleaning heat exchanger coil that automatically removes dirt and moisture. This helps to prevent unpleasant odors and to combat the formation of mold.
  • Jet Temperature Control
  • With the press of a button, your system will temporarily adjust the set point and fan speed to provide rapid heating or cooling.
  • Sleep Mode
  • With the sleep mode and timer functions, you can set the indoor units to save energy at night. Sleep mode will incrementally adjust temperature for an hour before the timer function automatically deactivates the unit.
  • Dehumidify
  • LG's mini split indoor units include a dehumidifying operation mode. In this mode, the unit's internal sensors monitor temperature and modify the set point and fan speed to remove moisture from the air.
  • Improved Air Quality
  • A washable anti-fungal filter is the first line of defense against dust and bacteria. This filter is backed up by a high air flow 3M Micro Protection Filter that captures microscopic irritants for pristine air quality.
  • Built-In Wi-Fi
  • With built-in Wi-Fi, you have the ability to control your LG air conditioner with smart enabled devices. Simply download the SmartThinQ® app on your smart device to get started.
  • Integrated Base Pan Heater
  • Factory-installed base pan heater in the drain pan. This prevents condensate from freezing and damaging the unit in frigid climates.
  • Product Note
    This product requires the following accessories for installation: Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor units. Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor units to drain locations of your choosing. We recommend locally purchased PVC hard pipe for the condensate drain on cassette and concealed duct units. Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box. Connecting Wire - This durable, insulated wire provides power to your indoor units from your outdoor condenser.Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.Adding these accessories to your order will provide a complete, ready-to-install mini split system. All Mini Split Systems require one Primary Mini Split Installation Kit.
    Bundle Includes 2 items
    Specifications
    View More

    Specifications

    Included In This Bundle

    Bundle Overviewgrey arrow icon
    Overview
    Product Category
    Mini Split Heat Pump System
    General Information
    Type
    Wall Mounted
    Product Category
    Mini Split Heat Pump System
    Operating Mode Learn More
    Operating Mode
    Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
    Heating and Cooling
    Number of Zones Learn More
    Number of Zones
    A zone is a room or area within a building that has its own temperature control.
    1
    Refrigerant Type
    R-410A
    Indoor Unit Size(s) Learn More
    Indoor Unit Size(s)
    Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
    18
    Base Pan Heater Included
    Yes
    Outdoor Unit Size
    18000 BTU
    DOE Regional Compliance Learn More
    DOE Regional Compliance
    In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
    Nationwide
    Line Set Size
    3/8" x 5/8"
    Performance
    Cooling BTU
    18000
    Cooling Capacity
    18000 BTU
    Heating Capacity
    21600 BTU
    Cooling Power Input
    1.43 Watts
    Low Ambient Heating
    Yes
    Minimum Outdoor Temperature for Heating Learn More
    Minimum Outdoor Temperature for Heating
    This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures.
    -4 F
    Minimum Outdoor Temperature for Cooling
    14 F
    SEER2 Learn More
    SEER2
    The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. SEER2 (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER2, the more energy efficient the system.
    22
    EER2 Learn More
    EER2
    The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. EER2 (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER2, the more efficient the system.
    12.58
    HSPF2 Learn More
    HSPF2
    The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. HSPF2 (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF2, the more efficient the system.
    9.5
    Electrical Data
    Voltage
    208/230 Volts
    Phase
    1
    Frequency
    60 Hz
    Dimensions
    Product Weight
    154 Pounds
    Shipping Weight
    178 Pounds
    Certifications
    CSA Listed
    Yes
    AHRI Certified
    Yes
    AHRI Reference Number
    207348503
    Warranty Information
    Parts Warranty Show ACW Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
    5 Years
    Compressor Warranty
    7 Years
    General Information
    Type
    Outdoor Condenser
    Product Line
    High-Efficiency
    Operating Mode Learn More
    Operating Mode
    Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
    Heating and Cooling
    Maximum Number of Zones
    1
    Multi-Zone Compatible
    No
    Refrigerant Type
    R-410A
    Installation Location
    Outdoor
    Performance
    Cooling BTU
    18000
    Heating BTU
    21600
    Maximum Sound Level Learn More
    Maximum Sound Level
    Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
    55 dB
    Low Ambient Heating
    Yes
    Minimum Outdoor Temperature for Heating Learn More
    Minimum Outdoor Temperature for Heating
    This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures.
    -4 F
    Minimum Outdoor Temperature for Cooling
    14 F
    Electrical Data
    Voltage
    208/230 Volts
    Phase
    1
    Frequency
    60 Hz
    Minimum Circuit Ampacity
    19 Amps
    Recommended Breaker Size
    30 Amps
    Dimensions
    Maximum Line Length
    114.8 Feet
    Gas Connection Size
    5/8 Inch
    Liquid Connection Size
    3/8 Inch
    Product Height
    31 1/2 Inches
    Product Width
    34 1/4 Inches
    Product Depth
    12 5/8 Inches
    Product Weight
    121 Pounds
    Shipping Weight
    131 Pounds
    Certifications
    UL Listed
    Yes
    ETL Listed
    Yes
    AHRI Certified
    Yes
    ISO Certified
    Yes
    Warranty Information
    Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
    5 Years
    Compressor Warranty
    7 Years
    General Information
    Type
    Wall Mounted
    Product Line
    Multi F
    Product Category
    Mini Split System Components
    Operating Mode Learn More
    Operating Mode
    Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
    Heating and Cooling
    Multi-Zone Compatible
    Yes
    Refrigerant Type
    R-410A
    Remote Control
    Wireless
    Indoor Unit Size(s) Learn More
    Indoor Unit Size(s)
    Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
    18
    Installation Location
    Indoor
    Performance
    Cooling BTU
    18000
    Cooling Capacity
    18000 BTU
    Maximum Air Flow
    706 CFM
    Minimum Air Flow
    371 CFM
    Minimum Sound Level
    31 dB
    Maximum Sound Level Learn More
    Maximum Sound Level
    Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
    47 dB
    Electrical Data
    Phase
    1
    Frequency
    60 Hz
    Dimensions
    Maximum Line Length
    114.8 Feet
    Gas Connection Size
    5/8 Inch
    Liquid Connection Size
    3/8 Inch
    Product Height
    13 7/12 Inches
    Product Width
    40 9/16 Inches
    Product Depth
    9 13/16 Inches
    Product Weight
    31 Pounds
    Shipping Weight
    36 Pounds
    Certifications
    ETL Listed
    Yes
    UL Listed
    Yes
    ISO Certified
    Yes
    Warranty Information
    Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
    5 Years
    Overview
    Product Category
    Mini Split System Components
    Reviews
    View More

    Reviews

    Do You Own This Product?

    Give us your opinion on this product and help any future buyer's make an informed decision.

    Manuals
    View More
     
    Share
    ×
    LG - 18k Cooling + Heating - Wall Mounted - Air Conditioning System - 22.0 SEER2
    LG LS181HSV5
    Loading
    LG LS181HSV5
    LG LS181HSV5
    LG LS181HSV5
    LG LS181HSV5
    ×
    Customer Review Images
    Loading
    Scroll Up ArrowTo Top