This and many other products are now available for order online and pickup at the Power Equipment Direct warehouse in Bolingbrook, Illinois or at a Ferguson location near you.
Answer:
Your nearest pickup location within a 50-mile radius is automatically selected when you enter the site. To change your pickup location and see availability for other nearby locations, click the "Change Pickup Location" link on the product page or in the cart.
Answer:
Eligible items will have the Local Pickup option available both on the product page and in the cart. Select this option for all items you wish to pick up. Please note that Local Pickup can only be scheduled online at this time.
Answer:
Items are usually ready for pickup the same day the online order is placed, but this will depend on order volume and time of day. When your order is ready, you will receive an email including specific pickup instructions. Make sure to check your junk/spam folder. Orders not picked up within two business days may be canceled. You should opt to have your items shipped if you cannot pick them up promptly.
Answer:
During checkout, you will be prompted to enter the name, mobile phone number, and email address of the person who will be picking up the order. For your protection, only you or your designated pickup party may pick up your order. You will need your order confirmation and a government-issued photo ID to pick up your order.
Answer:
Not all items are available at all locations, so pickup availability will vary based on the selected store. Additionally, some items ship directly from our manufacturer partners and are not available for pickup. You can use the "Change Pickup Location" link to check for availability at nearby Local Pickup locations.
Answer:
Due to packaging, shipping costs, and other factors, some items cannot be shipped and are offered exclusively through Local Pickup.
Answer:
Credit/debit cards, Apple Pay, Google Pay, PayPal, and financing are accepted for Local Pickup orders.
Answer:
Make sure to have your order confirmation and a government-issued photo ID available when picking up your order. Check the item dimensions and ensure the items will fit in your vehicle. Bring any straps and other materials that will be needed to secure the items for transport.
Revolv MG2S - 60k BTU - Two-Stage Gas Furnace - Manufactured Home - 96% AFUE - Front Return - Includes Coil Cabinet
New NewThis product is new and has never been used. It's in its original packaging, which has not been opened.
Product Category
Furnace
UPC
663132369959
View More
+Share This Product
Recommended Accessories
Required AccessoriesAdd All Required
Installation Accessories
Features
Features
Overview for Revolv MG2S-060F
Revolv is dedicated to bringing efficient comfort to the manufactured and mobile home market. The MG2S is a downflow gas furnace capable of providing 60,000 BTU of heating at 96% AFUE. Designed for easy installation in a variety of manufactured and modular homes, the MG2S features a small footprint and is HUD-compliant. The MG2S includes a 2-stage gas valve, allowing the furnace to produce as little as half the rated full-capacity to prevent short cycling and reduce energy consumption. Featuring a factory-installed coil box, the MG2S is ready to pair with an AC unit out of the box. With durable construction and a dependable warranty, the Revolv MG2S is a reliable solution for your manufactured home heating needs.
High Efficiency Heating
Revolv MG2S furnaces are designed to save you money. Sporting a 96% AFUE efficiency rating, Revolv's high efficiency line will provide heat while keeping money in your pocket.
2-Stage Gas Valve
A 2-stage gas valve allows for low fire-rate furnace operation to run at as little as half of the rated full capacity, preventing short cycling and reducing energy costs.
ECM Motor
The MG2S includes a high efficiency ECM blower motor, granting powerful CFM ratings at the fraction of the energy costs of traditional PSC motors.
Specifications
Specifications
Overview
Product Category
Furnace
UPC
663132369959
General Information
Type
Gas Furnace
Product Line
MG2S
Product Category
Furnace
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Two Stage
Blower Motor Type
ECM Fixed Speed
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Gas Conversion Kit
Included
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
96 %
Heating BTU
60000
High Fire Input
60000 BTU
High Fire Output
57600 BTU
Low Fire Input
39000 BTU
Low Fire Output
37400 BTU
Maximum Air Flow
1646 CFM
Ultra Low NOx Emissions Ultra Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
No
Low NOx Emissions Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx.
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 or 3 Inches
Gas Connection Size
1/2 Inch
Cabinet Width
19 7/8 Inches
Product Height
76 Inches
Product Width
19 7/8 Inches
Product Depth
24 5/8 Inches
Shipping Weight
179 Pounds
Certifications
AHRI Certified
Yes
AHRI Reference Number
203049796
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Reviews
Reviews
Do You Own This Product?
Give us your opinion on this product and help any future buyer's make an informed decision.
+Thank You For Submitting Your QuestionYour submission has been sent successfully. Please give our product specialists up to two business days to respond.
Continue Shopping
×
Revolv MG2S - 60k BTU - Two-Stage Gas Furnace - Manufactured Home - 96% AFUE - Front Return - Includes Coil Cabinet